CORENET X update, from 1 Oct 2026 the mandate applies at GFA ≥ 5,000m², including major A&A.What changed
Learn · Regulation

Green Mark v7

BCA replaced Green Mark 2021 with Version 7 on 2 September 2026. Energy now has its own certificate, there is a new top Super Low Energy tier, and existing buildings get easier routes to recognition. What changed, and what it means for owners.

Green Mark Version 7 (GM v7) is BCA's refresh of Green Mark 2021, published and effective on 2 September 2026. The headline change is a split. A new, standalone BCA Energy Rating recognises a building on energy performance alone. The holistic Green Mark certificate then adds five sustainability sections on top. A building can hold the first without the second, which is the opening BCA has made for existing buildings.

Everything below comes from BCA's Green Mark v7 Certification Standard, first release dated 2 September 2026. The detailed criteria sit in the GM v7 Technical Guides for each building type, so treat this page as the overview and the Technical Guide as the rulebook.

Two certificates

The BCA Energy Rating is a standalone certification focused only on energy performance. BCA describes it as an alternative pathway for all building owners, particularly owners of existing buildings, to invest in energy efficiency and be recognised for it without pursuing holistic certification. A project pursuing only the Energy Rating receives one certificate.

The BCA Green Mark certification combines the Energy Rating with points across five sustainability sections: Intelligence, Health & Wellbeing, Whole Life Carbon, Resilience and Maintainability. Depending on the points achieved, a project attains GoldPLUS or Platinum. Buildings that pursue it receive two certificates, one for the Energy Rating tier and one for the holistic rating, and can display either or both.

Energy Rating tiers

TierNote
EE45Only for Green Mark In Operation, the recertification route for buildings already certified.
EE50, EE55Energy efficiency tiers.
SLE60Super Low Energy. Part of the GreenGov.SG requirement for public-sector buildings.
SLE70New in v7: at least 70% energy savings against the stipulated baseline.
ZE, PEZero Energy and Positive Energy.

What else changed

  • Alternative Cooling Technologies. Hybrid cooling, active chilled beams, passive displacement cooling, radiant cooling and mixed-mode ventilation can now offset shortfalls under the Fixed Metrics pathway, with other solutions considered on evidence.
  • A shorter Maintainability section. BCA has streamlined it by more than 50%, with a systems approach in place of attribute-by-attribute compliance.
  • Portfolio Certification. Owners of similar buildings can group them under one "parent" application and recertify them together under Green Mark In Operation.
  • 5-year validity. Certificates are valid for 3 years as standard. In Operation and Energy Rating certificates assessed under Pathway 1, Energy Use Intensity, can get 5 years where the building has met its EUI targets over the preceding 12, 24 and 36 months.
  • Chiller retrofits without full reassessment. See the next section.

Chiller retrofits

An existing Green Mark building replacing its chillers or upgrading major energy systems can recertify under Green Mark In Operation instead of a full reassessment, if all three of BCA's conditions hold:

  1. it previously held a full Green Mark certificate under any version (a provisional certificate does not count);
  2. it shows energy efficiency with actual measured operational data, not design-stage commitments; and
  3. the retrofit does not alter the building envelope or increase GFA in a way that triggers the environmental sustainability rules for new developments.

The third condition is the one to design around. Once envelope or GFA changes push the project into major A&A territory, it is assessed as an existing building with major retrofit. See A&A works for that threshold.

Who it covers

GM v7 full certification covers new developments at design and completion stage, existing buildings in operation with no previous Green Mark certification, and existing buildings with major retrofit, which BCA defines by reference to major A&A under the Building Control (Environmental Sustainability) Regulations. Green Mark In Operation is the simplified route for buildings already fully certified. GM v7 does not apply to office interiors, retail interiors or other fit-out projects.

Regulations alongside

Green Mark certification is voluntary. The standard lists the rules that are not:

  • Environmental sustainability regulations under the Building Control Act for new buildings and specified major A&A.
  • Existing buildings: minimum standards for specified major energy-use changes, periodic energy audits of cooling systems, and building energy benchmarking.
  • Mandatory Energy Improvement (MEI) for applicable energy-intensive buildings: an energy audit, an Energy Efficiency Improvement Plan, implementing the measures, and maintaining performance. The current regime took effect on 30 September 2025.
  • Government Land Sales sites carry higher standards, currently Green Mark Platinum Super Low Energy with the Maintainability Badge for applicable sites.
  • GreenGov.SG expects public-sector new buildings and major retrofits to reach Green Mark Platinum with an SLE60 Energy Rating, or equivalent.

Where we fit

Retrofit work on an existing building starts with knowing what is actually there. Energy modelling, chiller plant redesign and envelope upgrades all depend on drawings that match the building, and in older buildings the archived plans rarely do. 3D laser scanning captures plant rooms, ceilings and facades as they stand, delivered as as-built drawings or a Revit model your consultants can design and simulate in. For the Intelligence and Maintainability sections and long-term operations, the same capture becomes a digital twin. We do not certify buildings or act as Green Mark consultants; we give the people who do an accurate starting point.

Existing buildings, before the retrofit

Retrofitting for Green Mark? Scan and Revit model from S$3,000.

Energy models, chiller plant redesigns and envelope upgrades all start from drawings that match the building. We capture plant rooms, ceilings and facades as they stand and model them in Revit for your consultants. We do not certify buildings.

Scan and modelS$3,000

Site scan, registration and a Revit model at LOD 200 of a single floor or small unit.

Model from a point cloudS$1,600

Revit model at LOD 200 from a registered cloud: ours, or yours after a quality check.

Per item
  • Site scan, up to 2,000 sqftS$1,500
  • Revit model, LOD 200from S$1,600
  • LOD 300 and aboveQuoted
  • Rush: half the delivery time+30%

What moves the price: floor area, number of levels, LOD, which disciplines are modelled, and whether the model feeds a CORENET X submission.

Scan-to-BIM 3D laser scanning Digital twins

Frequently asked questions.

What is Green Mark v7?
Green Mark Version 7 is BCA's refresh of the Green Mark 2021 scheme, published on 2 September 2026. Its biggest change is splitting energy from everything else: a standalone BCA Energy Rating recognises energy performance alone, and the holistic Green Mark certificate adds five sustainability sections on top. Buildings pursuing both receive two separate certificates.
What are the BCA Energy Rating tiers?
EE45 (only for Green Mark In Operation), EE50, EE55, SLE60, SLE70, Zero Energy (ZE) and Positive Energy (PE). SLE70 is new in v7, for projects achieving at least 70% energy savings against the stipulated baseline. Green Mark 2021 had only one Super Low Energy tier.
Can an existing building get certified without full Green Mark?
Yes. That is the point of the new BCA Energy Rating. BCA describes it as an alternative pathway for all building owners, particularly owners of existing buildings, to improve energy efficiency and be recognised for it without pursuing holistic Green Mark certification.
How long is a Green Mark v7 certificate valid?
Three years as standard. Green Mark In Operation and Energy Rating certificates assessed under Pathway 1, Energy Use Intensity, can get an extended 5-year validity where the building has met its EUI targets over the preceding 12, 24 and 36 months.
Does a chiller replacement need a full Green Mark reassessment?
Not under v7, if three conditions are met: the building previously held a full Green Mark certificate under any version (a provisional one does not count), energy efficiency is shown with actual measured operational data, and the retrofit does not alter the envelope or increase GFA in a way that triggers the environmental sustainability rules for new developments. It can then recertify under Green Mark In Operation.
Is Green Mark mandatory?
The certification scheme itself is voluntary, but regulations sit alongside it. New buildings and existing buildings undergoing major A&A must meet the Building Control environmental sustainability requirements, existing buildings face periodic energy audits of cooling systems and benchmarking, and the Mandatory Energy Improvement regime, current form in effect from 30 September 2025, applies to energy-intensive existing buildings. Government Land Sales sites and public-sector buildings carry higher Green Mark requirements.

Planning a retrofit?

Tell us the building and what your consultants need to model. We will scope the capture and the deliverable to match.

Describe the building